Multi-para Patient Monitor
Code ID: Moni 5B
Model ID: Moni 5B
Certificate: ISO, CE
Min. Order: 1 PCS
Inquire
Print
 
Feature:
Multi-para Patient Monitor(Moni 5B)
Model: Moni 5B
 
A, outlook;
Moni 5B patient monitor is easy to carry,with 800*600  8inch color TFT-LCD screen,size of main unit is 175*210mm,thickness is 80mm,weight of main unit with battery is 1.35KG.  Packing carton of each unit is 13*38*27CM,weight of patient monitor with accessories and packing material is 2.6KG.
 
B, Features;
1, Waterproof design appearance,low power consumption,without air fan and silence,use 13—20V output DC,battery working time is at least 5.5hours,recharge time is 2.5hours. Suitable for medical field rescue, ambulance, move and transit.
2, display mode of big font, trend review, ECG 7 lead,support one key operation,touchable screen is optional. Suitable for all working places,can used for neonate,child,adult,support mode of diagnose, monitor, operation.
3, 15 type arrhythmic analysis,7-lead ECG waveform display in phase. 15 type drug calculation and titration table.
4, efficient resistance to interference of defibrillator and electrosurgical cautery,respiration can choose I\II,meet requirement of operation, ward.
5, use digital SpO2 technology,can test for 0.1% weak,high accuracy.
6, anti-ESU,anti-defibrillator,RA-LL impedance respiration,digital filtering.
7, double over-pressure NIBP protect,temperature drift.
 
Specification:
1.ECG
Lead mode  3-lead or 5-lead cable
3-leadRA, LA, LL,lead way:I,II,III
5-leadRA, LA, LL, RL, V,lead wayI,II,III,aVR,aVL,aVF,V
gain  ´250,´500,´1000,´2000
Heart rate rangeadult15 ~ 300bpm (pulse/min.)     neonate/child15 ~ 350 bpm(pulse/min.)
accuracy±1% or ±1bpm,
resolution1 bpm(pulse/min.)
sensitivity  >200 uV(peak-to-peak value)
Input resistance >5(mge)
bandwidth
Diagnostic mode0.05~130Hz
Monitor mode0.5~40Hz
Operation mode1~20Hz
Common mode rejection ratio
Diagnostic mode>90 dB
Monitor mode:>100 dB
Operation mode:>100 dB
Can test following
range±2 mV ~ ±700mV
width0.1ms ~ 2ms
rise time10us~100µs
When turn on pacemaker pulse,can restrain following data, does not influence pulse rate calculation
range:±2 mV ~ ±700mV
width:0.1ms ~ 2ms
rise time:10us ~ 100µs
Baseline recovery time after defibrillation< 3 seconds
Sign range ±8 mV (peak-to-peak value)
Calibrating signal 1mV(peak-to-peak value),accuracy  ±5%
ST measurement
Measure range-2.0mV ~ +2.0mV
Measure accuracyin range of -0.8 mV~+0.8mV  the tolerance is  ±0.02mV or ±10% take bigger one.
Undefinition in other range.
2.Respiration
Range: 0.3~3Ω
Band width 0.1~2.5Hz
Respiration rate
range adult2~120BrPM   child and neonate2~150 BrPM
resolution1 BrPM
accuracy±2 BrPM
Apnea alarm 10~40 seconds
Technology:Oscillometric
Mode: manual/auto/STAT
Measurement inerval time under auto mode is 1,2,3,4,5,10,15,30,60,90,120,180,240,480 minutes.
Measurement time under STAT mode is  5 minutes.
Pulse rate range   40~240 bpm
range
adult          SIS           40~270mmHg
                        DIA          10~215mmHg
                        mean 20~235mmHg
child          SIS           40~200mmHg
                        DIA        10~150mmHg
                        mean 20~165mmHg
              neonate   SIS         40~135mmHg
                               DIA          10~100mmHg
                               mean 20~110mmHg
Static pressure range      0~300mmHg
Static pressure accuracy        ±3mmHg
Blood pressure accuracy              maximum average error ±5mmHglargest standard deviation    8mmHg
Over-pressure protect
Adult mode               300 mmHg
Child mode                240 mmHg
Neonate mode        150 mmHg
 
range             0~100%
resolution                     1%
accuracy                70~100%±20%~69%undefinition
Pulse rate
range             20~300bpm
resolution                     1bpm
accuracy                ±3bpm
Channel number:  1 channel
range      0~50°C  resolution     0.1°C   accuracy  ±0.1°C(do not include error of probe)
 
Configuration:
Standard configuration
1. main unit(include battery)             1pc
2.5-lead ECG cable                1pc
3.surface temp.probe              1pc
4.adult NIBP cuff                 1pc
5.NIBP tube                       1pc
6.adult SpO2 sensor               1pc
7.power cord                      1pc
8.electrode                       1package
 
 
Optional functions
Touchable screen
CO2
 
Optional accessories
1, 14.8V2.2AH Li-ion battery
2, adult,pediatric,neonate(fingertip,finger stall,wrap) SpO2 sensor
3, adult,pediatric,neonate NIBP cuff
4, various CO2 sampling pipes
5, 3-lead,5-lead ECG cable in Euro or USA standard
6, surface and coelom temp.probe
 